FOR MVS6/LVS3 - small filter device
Bio inlet for disposable filter holder for sampling airborne moulds according to VDI 4252-2. Flow rate: 3 m³/h. Use of filters with a diameter of 80 mm. Simple handling, the disposable filter holder is to be stuck on an adapter and is sealed by an O ring.
- Impactor inlet: X = 10 µm - 4,0 µm - 2,5 µm - 1,0 µm
- PM10 reference inlet according to CEN EN 12341
- PM2,5 standard inlet according to CEN EN 14907
- Exchangeable jets (1 set: 8 pieces, each) for PM10 - PM4,0 - PM2,5 - PM1,0
- All jets available for 3,5 m³/h - 3,0 m³/h - 2,3 m³/h - 1,0 m³/h
- Exchangeable impaction plate
- Deep well, below impaction plate for e.g. condensed water
- Special cassettes for filters
- Use of filters with diameters of 47 mm and 50 mm
Pre-impactor: X = 10 µm - 4,0 µm - 2,5 µm - 1,0 µm
- Sampling of PAHs according to the European Directive 2004/107/EC
- Exchangeable jets (1 set: 8 pieces, each) for PM10 - PM4,0 - PM2,5 - PM1,0
- All jets available for 3,5 m³/h - 3,0 m³/h - 2,3 m³/h - 1,0 m³/h
- Exchangeable impaction plate
- Special cassettes for filters
- Use of filters with diameters of 47 mm and 50 mm
- The inner tube of the PU cartouche is made of glass
- The glass tube is capable to take in up to 3 PU foam pieces (diameter 45 mm , height 50 mm)
Pre-impactor: X = 10 µm - 4,0 µm - 2,5 µm - 1,0 µm. Sampling of PAHs according to the European Directive 2004/107/EC and CEN EN 15549 (BaP). Scrubber (ozone denuder) easily accessible. Interference of the scrubber's efficiency with humidity is negligible up to 80 % r. h. Continuous operation of the scrubber over approximately 1 month. Scrubber housing and scrubber sealed by O-rings. Exchangeable jets (1 set: 8 pieces, each) for PM10 - PM4,0 - PM2,5 - PM1,0 . All jets available for 3,5 m³/h - 3,0 m³/h - 2,3 m³/h - 1,0 m³/h. Exchangeable impaction plate. Special cassettes for filters. Use of filters with diameters of 47 mm and 50 mm. The inner tube of the PU cartouche is made of glass. The glass tube is capable to take in up to 3 PU foam pieces (diameter 45 mm, height 50 mm).
PU INLET KFG
TSPM measurement according to VDI 2463-8. Measurement of PCB according to VDI 2464-1 and ISO 16000-13. Measurement of PCDD and PCDF according to VDI 3498-2 and ISO 16000-13. Measurement of PCP / lindane according to VDI 4301-2. Measurement of PAHs according to ISO 12884. Special cassettes for filters. Use of filters with diameters of 47 mm and 50 mm. The inner tube of the PU cartouche is made of glass. The glass tube is capable to take in up to 3 PU foam pieces (diameter 45 mm, height 50 mm).
TSPM inlet according to VDI 2463-8. Flow rate: 2,7 - 3 m³/h. Special cassettes for filters. Use of filters with diameters of 47 mm and 50 mm.
for sequential samplers SEQ 47/50
PMX INLET - SCRUBBER SEQ
Pre-impactor: X = 10 µm - 4,0 µm - 2,5 µm - 1,0 µm, BaP (PAH) measurement according to CEN EN 15549, Scrubber (ozone denuder) easily accessible, Interference of the scrubber's efficiency with humidity is negligible up to 80 % r. h., Continuous operation of the scrubber over approximately 1 month, Scrubber housing and scrubber sealed by O-rings, Exchangeable jets (1 set: 8 pieces, each) for PM10 - PM4,0 - PM2,5 - PM1,0 , All jets available for 4,0 m³/h - 3,5 m³/h - 3,0 m³/h - 2,3 m³/h - 1,0 m³/h, Exchangeable impaction plate
PMX INLET SEQ
Impactor inlet: X = 10 µm - 4,0 µm - 2,5 µm - 1,0 µm, PM10 reference inlet according to CEN EN 12341, PM2,5 standard inlet according to CEN EN 14907, Exchangeable jets (1 set: 8 pieces, each) for PM10 - PM4,0 - PM2,5 - PM1,0, All jets available for 4,0 m³/h - 3,5 m³/h - 3,0 m³/h - 2,3 m³/h - 1,0 m³/h, Exchangeable impaction plate, Drainage bottle available (to be attached below the impaction plate according to CEN EN 14907)
TSPM INLET SEQ
TSPM inlet according to VDI 2463 parts 5 and 8, Flow rate: 3 m³/h, Suction opening protected by mesh
For MiniVS
PMX INLET 47-50mm MINI
Impactor inlet: X = 10 µm - 2,5 µm. Use of filters with diameters of 47 mm and 50 mm. Single jet impactor. The impactor can be equipped with one PM10 or one PM2,5 jet for flow rates of 100 l/h or 200 l/h, each. Special cassettes for filters. Sampling time: approximately 1 week up to 1 month.
PMX INLET 25mm MINI
Impactor inlet: X = 10 µm - 2,5 µm. Use of filters with a diameter of 25 mm. Single jet impactor. The impactor can be equipped with one PM10 or one PM2,5 jet for flow rates of 100 l/h or 200 l/h, each. Special cassettes for filters. Sampling time: approximately 1 week.